Full Scale |
Bench Scale |
Madison, WI |
Literature |
MFC has demonstrated its full-scale, 4-element unit at several locations throughout the U.S., including WI, OH, VA, NC, & TX.
|
Several small 'bench-scale' test systems are available for preliminary performance testing of odd or irregular waste types or solids loadings. Bench-scale units are available in sizes from 0.5 - 5 gpm and are perfect for preliminary testing on systems utilizing polymers, flocculants, or other filter specific treatments. |
MFC's full-scale, 4-element filter was operated succesfully at Madison, WI's Metropolitan Sewerage District from April 2006 through October 2007. A sidestream of 0.6-0.8 MGD was treated to reuse quality levels. Effluent TSS was consistently below 4 mg/l with several grab samples below detection limits of 1.1 mg/l. Turbidity, measured as NTU, was also significantly reduced to below 1.5 NTU, with the majority of samples reduced to sub 1.0 NTU levels. |
|
|
Muni-Disk® & Statiks™ - The Evolution of Cloth Media Filtration. |
|||
|
All information contained herein is property of Municipal Filtration Co., LLC (MFC). |
|||